Catalog navigation
CAD model selection
Model Code
MT4SA04010.815015024WFAARFSWXXTLXXXXXXXAAXXXXXXXX
Model
(MT) Magne-Trac™
Material of Construction
(4S) 304SS/304L Chamber/Flanges
(4C) 304SS/304L Chamber/Carbon Steel Flanges
(6S) 316SS/316L Chamber/Flanges
(6C) 316SS/316L Chamber/Carbon Steel Flanges
(MN) Monel 400 Chamber/Flanges
(HC) Hastelloy C276 Chamber/Flanges
(CP) CPVC Chamber/Flanges
(A2) Alloy 20
(CS) Customer specified
MLI Style
Vessel Connection Size
(04) 1/2"
(06) 3/4"
(08) 1"
(12) 1-1/2"
(16) 2"
(24) 3"
(CS) Customer Spec
Float Length/Dead leg
Contact factory for actual float length.
Float length parameter
Flange Option
RF (default)
(RJ) Ring Joint
(SL) Stub End/Lap Joint
Flange Option
(SW) Socket Weld
(SO) Slip-On
(WN) Weld Neck
Chamber Option
(XX) None (default)
(BW) Butt Weld Tee Connection(Full Bore)
Flange Class
(01) 150#
(03) 300#
(06) 600#
(09) 900#
(15) 1500#
(25) 2500#
(XX) None
Total Level or Interface Level
(TL) Total Level
(IF) Interface Indication
Specific Gravity - Upper (lighter)
0.000
Specific Gravity
Maximum Operating Pressure
PSIG
Maximum Operating Temperature
F
Center to Center Distance
Indicator Style
(WF) Wide Flag
(HF) High Temp Flag
(XX) None
Indicator Position
Indicator Style Submenu
(BY) Black/Yellow (Standard)
(WR) White/Red
Indicator Scale Single/Dual
(OS) One Scale
(DS) Dual Scale
Indicator Scale Options
(X) Feet/Inch (standard)
(MS) Metic -mm/M
(PS) Percent Scale - 10% increments
(SS) Custom Scale
Indicator Scale Options 2
(XX) Not Avaliable
Indicator Style Options
(XX) None
(FE) Non-Frost Extension
(AR) Arrow Pointer
Scale/Indicator Option
(XX) None
(SH) Stainless Steel Housing
Chamber Option2
(XX) None(default)
(IV) Inverted Chamber
Vent/Drain Connection Size
(AA) 1/2" Vent & Drain
(BB) 3/4" Vent & Drain
(CC) 1” Vent & Drain
(AX) 1/2” Vent, NO Drain
(XA) No Vent,1/2" Drain
(BX) 3/4" Vent, No Drain
(XB) No Vent, 3/4" Drain
(CX) 1” Vent, No Drain
(XC) No Vent,1” Drain
(XX) NO Vent & Drain
(CS) Customer Specified
Vent/Drain Connection Size Submenu
(F) F.NPT with plug
FSW
RF Flange
(M) M.NPT with cap
MSW (male socket weld)
Vent Valve - ALL OPTIONS NOT DEPICTED
(XX) None(default)
(GNN) Gate NPT x NPT
(GSN) Gate SW x NPT
Vent Valve
(XX) None
Drain Valve - ALL OPTIONS NOT DEPICTED
(XX) None(default)
(GNN) Gate NPT x NPT
(GSN) Gate SW x NPT
Drain Valve
(XX) None
Temp Maintenance Option 1
(XX) None
(EH) Electric Heat Trace, 120 VAC, 20W/ft
(ST) Steam Trace
Temp Maintenance Option 1Sub
(XX) None
Temp Maintenance Option 2
(XX) None
(HB) Heat Insulation Blanket
(CI) Cold Insulation with Non-Frost Extension
Transmitter Options
Transmitter Position
(XX) None
Switch Options
(XX) None
(R1) MTLS-1A: 1 Amp Magnetic Level Switch
(R5) MTLS-5A: 5 Amp Magnetic Level Switch
(R10) MTLS-10A: 10 Amp Magnetic Level Switch
Switch Position
(XX) None
Switch Quantity
0
Customer Specified
Customer Name
Tag
Download CAD models
Previews
Embedded user actions